111. Solving a chemistry problem
Seller: Derkach
Price: 1.19 USD
Available. The final price depends on the selected options and is checked before payment.
Product description
- To determine copper by the polarographic method, a sample of the alloy 0.5004 g was taken, which was transferred to a volumetric flask with a capacity of 50 cm3. For polarography, 20.00 cm3 of the obtained solution was taken; the height of the polarographic wave was 24 mm. When polarography of the same volume of a standard solution containing 0.8 mg of copper (ll), a polarographic wave 20 mm high was obtained. Calculate the percentage of copper in the alloy.
Additional information
If you do not open the file - install the RAR archiver. Inside the archive you will find a solution in Word format.